Ask a refinery manager whether the site has hazardous areas and the answer is yes before you finish the question. Ask a bakery, a joinery or a wastewater plant and there is often a pause. Yet flour, wood dust and sewage gas can all form explosive atmospheres, and regulators in Europe, the UK and North America treat them that way.

This article looks at where explosive atmospheres tend to form in industries that do not see themselves as hazardous, what those places have in common, and how the main regulatory frameworks deal with them.

The pattern: it is rarely the whole site

Most facilities with an explosion risk are not hazardous from wall to wall. The explosive atmosphere forms in specific places, and those places follow a pattern. Four situations account for most of them:

  • Inside equipment. Dust collectors, filters, silos, bucket elevators, mills, dryers, digesters and covered tanks. The material is concentrated and enclosed, which is exactly what an explosive mixture needs. In many dust-handling plants the most hazardous place is inside the filter, not on the production floor.
  • At points of transfer. Filling, emptying, bagging, tipping, pumping and conveying. Wherever material moves from one container to another, some of it escapes as dust or vapour.
  • Where the process creates it. Spraying creates mist and vapour, sanding and grinding create dust, shredding releases whatever was left inside the waste, and charging lead-acid batteries releases hydrogen.
  • When the routine changes. Cleaning, maintenance, opening a normally closed system, tank entry or a process upset. Precautions are usually designed around normal operation, so non-routine work deserves separate attention.

Looking at a site through these four lenses is often more useful than asking whether the site as a whole "is ATEX".

Infographic: four places where explosive atmospheres form, three questions for every area, and how ATEX, DSEAR, NEC and IECEx classify them
Where explosive atmospheres form: four kinds of places, three questions for every area, and how the frameworks classify them.

Industries that often underestimate the risk

IndustrySubstanceWhere to look first
Bakeries, flour mills, sugar and confectioneryFlour, sugar, starchSilos, sifters, mills, sugar grinders, dust extraction
Grain storage and animal feedGrain and feed dustBucket elevators, conveyors, intake pits, silos
Dairy and food ingredientsMilk powder, lactoseSpray dryers, bagging, filters
Woodworking and furnitureWood dustExtraction ductwork, cyclones, filters, sanding lines
Metalworking and foundriesAluminium and magnesium dustGrinding and polishing areas, dust collectors
Pharmaceuticals and cosmeticsEthanol, solvents, powdered excipientsGranulation, drying, coating, solvent stores
DistilleriesEthanol vapourStills, spirit receivers, filling, warehouses
Breweries and maltingsMalt and grain dustIntake, milling, dust extraction
Paint shops and coating linesSolvent vapour, overspray, coating powderSpray booths, mixing rooms, drying ovens
Wastewater treatmentMethane, hydrogen sulphideInlet works, pumping stations, covered tanks, sludge treatment
Biogas and anaerobic digestionMethaneDigesters, gas holders, CHP units
Waste and recyclingResidues in aerosols and cylinders, paper and plastic dust, methaneShredders, waste bunkers, baling areas
Coal handling, cement and powerCoal dustCoal mills, bunkers, conveyors
Any site with forkliftsHydrogen, LPGBattery charging areas, LPG storage and refuelling

For the properties behind these risks, see our articles on flash point, vapour density and CO2 inerting in coal grinding.

Dust deserves extra attention

Most people recognise a gas leak as dangerous. Dust is taken less seriously, and two things make it different.

Secondary explosions. A small primary explosion inside a piece of equipment can shake loose dust that has settled on beams, ducts and ledges, and ignite it. The result can be a much larger explosion that travels through the building. That makes housekeeping part of explosion protection, not just tidiness. In US practice, a dust layer of 1/32 inch (about 0.8 mm) is often used as a warning threshold. That is thinner than most people expect.

Particle size. The same material can behave very differently depending on how fine it is. A new supplier, an extra grinding step or a finer product grade can change the risk without anyone touching the process itself. Parameters such as Kst and minimum ignition energy are measured on a specific sample, so they are only valid for material like that sample. Our overview of dust explosion risk parameters explains each one.

Where dust and solvent vapour occur together, as in some pharmaceutical processes, the combination (a hybrid mixture) can be easier to ignite than either on its own.

How the rules compare

The frameworks differ in terminology, but they follow the same logic: identify where an explosive atmosphere can occur, classify those areas, use suitable equipment in them, and keep it that way.

RegionWorkplace obligationArea classificationEquipment
European UnionATEX workplace directive 1999/92/ECZones 0, 1, 2 (gas) and 20, 21, 22 (dust)ATEX equipment directive 2014/34/EU
United KingdomDSEAR 2002Zones 0, 1, 2 and 20, 21, 22UKEX regulations
United StatesOSHA 29 CFR 1910.307, NFPA 652 for combustible dustNEC Class I, II, III with Division 1 or 2 (Article 500), or Zones (Articles 505 and 506)Certified by a Nationally Recognized Testing Laboratory
CanadaProvincial occupational health and safety rulesCanadian Electrical Code Section 18 (Zones) or Annex J (Class and Division)Certified for use in Canada
InternationalIECEx schemeIEC 60079-10-1 (gas) and IEC 60079-10-2 (dust)IECEx certificate of conformity

A few points worth knowing:

  • In the US, NFPA 652 requires a Dust Hazard Analysis for facilities that handle combustible dust, and OSHA runs a National Emphasis Program on combustible dust. The industries in the table above are exactly the ones it covers.
  • Class and Division and the Zone system describe similar risks in different ways. Our FAQ explains how they relate, and our North American certifications page lists equipment per Class and Division.
  • Equipment certified under one system is not automatically accepted under another. An ATEX-certified device is not by definition approved for a Class I, Division 1 location, and the reverse also applies. Check the marking against the local requirements. See decoding ATEX marking.
  • People need competence too. Schemes such as CompEx in the UK and the IECEx Certificate of Personnel Competence internationally cover work on equipment in hazardous areas. Note that "ATEX certification" applies to equipment, not to people or organisations.

A practical way to start

Instead of working through an industry checklist, ask three questions for each area of the site:

  1. What could burn if it were finely divided or evaporated? Include powders, fuels, solvents, cleaning products and anything stored temporarily.
  2. Where can it escape or build up? Use the four situations above: inside equipment, at transfer points, where the process creates it, and during non-routine work.
  3. What could ignite it there? Electrical equipment, hot surfaces, static electricity, friction and mechanical sparks, and hot work.

Where all three answers meet in one place, that place needs a proper assessment under the framework that applies to you, carried out by someone competent in area classification. It is also worth repeating the exercise whenever something changes: a new material, a new extraction system (which itself may create a classified area inside it) or a new layout.

Need equipment for a classified area?

Once your zones or classes are known, Specifex can help you find equipment certified for them, from intrinsically safe phones and tablets to lighting, ventilation and air conditioning, with ATEX, IECEx and North American certifications. See explosion-proof equipment selection, select your hazardous area, or request a quote with your zone and application.