Class 1 Div 1 Equipment: Intrinsically Safe Devices

Class 1 Div 1 equipment carries an approval for locations where flammable gases or vapors are present under normal operating conditions. This collection centers on intrinsically safe devices. You will find smartphones and tablets from i.safe MOBILE, ecom and BARTEC. In addition, there are flashlights and headlamps from NightSearcher and Underwater Kinetics.

HMi Elements panels, NightSearcher Titan work lights and a Peli remote area light complete the range. Moreover, you may also use Class I Division 1 equipment in Division 2 of the same class and group.

35 products

What Class I Division 1 Equipment Means

North America classifies hazardous locations under NEC Article 500 in the USA and the CEC in Canada. Class I stands for flammable gases and vapors. Division 1 means that this hazard is present under normal operating conditions. Class 1 Division 1 equipment, or C1D1 equipment for short, therefore holds an approval for these areas. In addition, a Division 1 approval also covers Division 2 of the same class and group.

Intrinsically Safe and Explosion Proof Class 1 Div 1 Devices

Most products in this collection are intrinsically safe. Intrinsic safety (Ex i) limits the energy in the circuits, so sparks or heat cannot ignite the atmosphere. For example, the i.safe MOBILE IS540.1 smartphone and IS930.1 tablet carry the marking Class I, II, III Division 1. The same applies to the ecom Ex-Handy 10 DZ1 phone.

Other products, however, use a flameproof enclosure (Ex d). Such an enclosure withstands an internal explosion and prevents it from spreading. The NightSearcher Titan rechargeable work light and the HMi Elements 800/900-Z1 panel follow this concept. North American buyers know it as explosion proof.

What to Check When Choosing C1D1 Equipment

  • Class, division and groups: most products here carry Class I Division 1, Groups A, B, C, D.
  • Temperature class: T4 limits the surface temperature to 135 °C and T6 to 85 °C. For instance, the ecom Tab Ex 03 DZ1 tablet has a T6 marking.
  • ATEX marking: the phones and tablets usually carry II 2G Ex ib IIC for Zone 1. IIC is the most demanding gas group. Flashlights such as the NightSearcher SafAtex Sigma 3C, however, carry II 1G Ex ia for Zone 0.
  • IP rating: the i.safe MOBILE phones have an IP68 rating. IP68 means dust tight plus protection against continuous immersion, as the manufacturer specifies.

Class 1 Division 1 Equipment by Product Type

Do you need one specific product type? Then go straight to Class 1 Div 1 tablets, Class 1 Div 1 cameras or Class 1 Div 1 flashlights. For areas where gas is present only under abnormal conditions, the Class 1 Div 2 equipment range offers more choice. Finally, our article on methods of protection explains Ex i and Ex d in more detail.

Frequently asked questions

Can Class 1 Div 1 equipment be used in a Class 1 Div 2 area?

Yes, equipment approved for Division 1 may also be used in Division 2 of the same class and group. Take the i.safe MOBILE IS530.1, marked Class I Division 1, Groups A, B, C, D. This phone therefore also covers Class I Division 2 areas with those groups.

Is there a Class 1 Div 1 camera or tablet in this collection?

Yes, both. The i.safe MOBILE IS930.1 and the ecom Tab Ex 03 DZ1 are tablets marked Class I Division 1. The RealWear Navigator Z1 head-mounted tablet with thermal camera carries Class I, Division 1, Groups A, B, C, D. The BARTEC Pixavi Cam is an intrinsically safe camera marked Class I, Zone 0, AEx ia IIC T4 Ga.

What is the difference between intrinsically safe and explosion proof Class 1 Div 1 equipment?

Intrinsically safe equipment keeps the energy in its circuits so low that sparks or heat cannot ignite the atmosphere. Explosion proof equipment has an enclosure that withstands an internal explosion and stops it from spreading. Here, phones, tablets and flashlights are mostly intrinsically safe, while the Titan rechargeable work light uses the enclosure concept.