Zone 2 HMI and ATEX Zone 2 Panel PCs

Looking for a Zone 2 HMI? This collection shows the full HMi Elements range for that zone. In Zone 2, an explosive gas atmosphere is not likely in normal operation. The HMi 1302-Z2 is the dedicated model for Zone 2 and Zone 22. Its marking includes Ex nA, IIC T4 Gc and Ex tc.

In addition, the HMi 470-Z1, HMi 1301-Z1 and HMi 800/900-Z1 are Zone 1 panels. Each of them therefore works as an ATEX Zone 2 panel PC too. Request a quote for your Zone 2 operator panel.

ATEX Zone 2 HMI: zone and category

Zone 2 is an area where an explosive gas atmosphere is not likely in normal operation. If it does occur, it lasts only for a short period. ATEX category 3G, with equipment protection level Gc, fits this zone. Moreover, category 2G equipment for Zone 1 is suitable for Zone 2. A Zone 2 buyer can therefore choose from both groups. Whether you call the unit a Zone 2 touch screen, operator panel or panel PC, the same marking applies.

ATEX Zone 2 panel PC: dedicated model or Zone 1 panel

The HMi Elements range offers two routes into Zone 2:

  • Dedicated Zone 2/22 model: the HMi 1302-Z2 with II 3(3)GD Ex nA [ic Gc] IIC T4 Gc and Ex tc IIIC T135°C Dc, IP66.
  • Zone 1 panels with IP66: the HMi 470-Z1 (Ex e ib mb [ib] IIC T4 Gb) and the HMi 1301-Z1 (Ex eb mb op is [ib] IIC T4 Gb).
  • Flameproof Zone 1 panel: the HMi 800/900-Z1 (II 2 G Ex d IIB Gb T6).

The Gb panels suit plants that want one model for Zone 1 and Zone 2. Only those units are on the Zone 1 HMI page.

What to check: gas group, temperature class and IP rating

First, confirm the gas group. The 1302-Z2, 470-Z1 and 1301-Z1 carry IIC, the most demanding group, which includes hydrogen and acetylene. The 800/900-Z1, in contrast, carries IIB. Second, check the temperature class. With T4, the surface temperature stays at or below 135 °C. Third, compare the IP rating. Our IP rating guide explains both digits.

ATEX HMI for Zone 2, Zone 22 and Class I Div 2

Is there dust in the same area? Then see the Zone 22 HMI panels. For North America, the HMi 1302-Z2 also has a listing for Class I, Div 2, Groups A, B, C, D. You find it under Class 1 Div 2 HMI. In addition, the ATEX HMI overview shows the whole range on one page.

Frequently asked questions

Which ATEX category does a Zone 2 HMI need?

A Zone 2 HMI needs ATEX category 3G, which matches equipment protection level Gc. Category 2G panels for Zone 1 are suitable as well. The HMi 1302-Z2 carries II 3(3)GD with Gc, while the other panels in this collection carry Gb.

Is there a Zone 2 HMI that is also rated Class 1 Div 2 (C1D2)?

Yes, the HMi 1302-Z2. Its Zone 2 marking includes Ex nA and IIC T4 Gc. It also has a listing for Class I, Div 2, Groups A, B, C, D with temperature code T4. In North America, Division 2 describes locations where the hazard is present only under abnormal conditions.

Can an ATEX Zone 2 panel PC also be used in dust areas?

Yes, when it carries a dust marking. The HMi 1302-Z2 has Ex tc IIIC T135°C Dc for Zone 22. The HMi 470-Z1 and HMi 1301-Z1 carry an Ex tb marking and list Zone 21 and Zone 22. These models have an IP66 rating.